Molecular Diagnosis Of Brucella Zoonosis As Blood Transfusion Hazard In Metropolitan Population Of Lahore And Okara (Record no. 13613)

000 -LEADER
fixed length control field 02430nam a22002177a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20170921112313.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 170921b2017 xxu||||| |||| 00| 0 eng d
041 ## - LANGUAGE CODE
Language code of text/sound track or separate title eng
082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER
Classification number 2873-T
100 ## - MAIN ENTRY--AUTHOR NAME
Personal name Amna Azam (2011-Va-3560
110 ## - MAIN ENTRY--CORPORATE NAME
Location of meeting Dr. Wasim Shehzad
245 ## - TITLE STATEMENT
Title Molecular Diagnosis Of Brucella Zoonosis As Blood Transfusion Hazard In Metropolitan Population Of Lahore And Okara
260 ## - PUBLICATION, DISTRIBUTION, ETC. (IMPRINT)
Year of publication 2017
300 ## - PHYSICAL DESCRIPTION
Number of Pages 78p.;
502 ## - DISSERTATION NOTE
Dissertation note Brucellosis and Coxiellosis are one of the most spreading zoonotic diseases. They both are facultative, intracellular, Gram negative and involved in bioterrorism and agro-terrorism attacks. Brucella abortus and Brucella melitensisare common among all specie of Brucella. Total two hundred Human Blood transfusion samples were collected from hospitals of Okara and Lahore. Blood was collected in vacutainers (without EDTA). After serum isolation serological test RBPT were performed of all samples. Eighty nine out of two hundred were positive to RBPT with seroprevalence of 44.5% (95% Confidence Interval [CI]: 37.61 – 51.4). DNA extraction was done. The concentration of DNA was analyzed through Nanodrop 2000. Then these samples were subjected to Genus specific Real-time PCR analysis. Forty one out of two hundred were positive to Genus specific Real-time PCR with seroprevalence of 20.5% (95% Confidence Interval [CI]: 14.9 – 26.09). Brucella genus positive samples were subjected to two species specific PCR Brucella abortus and Brucella melitensis respectively. Forty one out of forty one Brucella genuspositive samples were positive to Brucella melitensisand none of the sample was positive to Brucella abortus. These two hundred DNA samples were then subjected to Coxiella specific Real-time PCR analysis and 4 were found positive with seroprevalence of 2% (95% Confidence Interval [CI]: 0.06 – 3.94). Results were recorded in the form of Ctvalue. Results indicate that Real-time PCR is more efficient than RBPT and due to increasing seroprevalence in Blood transfusion samples its screening should be included in normal blood transfusion screening procedure through collaboration with Government to prevent transfusion transmitted infections (TTI’s).
650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical Term Molecular Biology And Biotechnology
710 ## - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Dr. Iahtasham Khan
710 ## - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Dr. Muhammad Imran
710 ## - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Dr. Imran Rashid
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type Thesis
Holdings
Damaged status Collection code Permanent Location Current Location Shelving location Date acquired Full call number Accession Number Koha item type
  Veterinary Science UVAS Library UVAS Library Thesis Section 2017-09-21 2873-T 2873-T Thesis


Implemented and Maintained by UVAS Library.
For any Suggestions/Query Contact to library or Email:[email protected] Phone:+91 99239068
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.