Comparative Evaluation Of Different Suture Materials With And Without The Usage Of Thomas Splint For The Repair Of Transversely Cut Tendo Achilles In The Dog
By: Hassan Saqlain | Muhammad Arif Khan.
Contributor(s): Dr. Muhammad Younas | Dr. Shakil | Faculty of Veterinary Sciences.
Material type: BookPublisher: 1997Subject(s): Department of Clinical Medicine & SurgeryDDC classification: 0516,T Dissertation note: Tendons are an important link In the locomotive system, the main physiological function of which is to transmit forces that produce characteristic mechanical responses. The tendon function is extremely important in movement. Injuries and disturbances in tendon are common, thus creating extreme difficulties in locomotion. The repair of tendons had always been an enigma in the past. However with the advancement of surgery, the repair of tendon has become possible and the patient return to a normal functioning life. The present study was launched on twelve mongrel dogs. The achilles tendon was cut surgically and then repaired with two different suture materials i.e. stainless steel and Nylon (No.1). Three groups were made i.e. group A, B and C. Group A for repair of the achilles tendon with stainless steel wire (gauge 24) alongwith a comparison of repair with and without a thomas splint. The group 'B' was repmred with Nylon suture material (No.1) as well as with the comparison of thomas splint application The group C served as a control group in which no suture material was used, however the effect of thomas splint was compared with and without its application. Of the twelve animals, four were put into each group. In every group, first the achilles tendon of the right hindlimb was repaired with and without thomas splint. After eight weeks healing, the tendo-achilles of the left hind limb was repaired with the same suture material with and without thomas splint. The wounds were smeared with furacin ointment. Antibiotics were administered 24 hours prior to surgery and continued for 5 days post-surgically. All the dogs were kept under observation for eight weeks postsurgically. however, the total project took 16 weeks. The tendons were tested for repair (healing) by examination, lameness tests, posteuthanasia finding and histopathological studies. The success rate of the tendons repaired with stainless steel sutures (guage 24) was 50% and with Nylon suture material (No. 1) 100%. The results clearly Indicated that the application of Nylon.Item type | Current location | Collection | Call number | Status | Date due | Barcode | Item holds |
---|---|---|---|---|---|---|---|
Thesis | UVAS Library Thesis Section | Veterinary Science | 0516,T (Browse shelf) | Available | 0516,T |
Browsing UVAS Library Shelves , Shelving location: Thesis Section , Collection code: Veterinary Science Close shelf browser
Tendons are an important link In the locomotive system, the main physiological function of which is to transmit forces that produce characteristic mechanical responses. The tendon function is extremely important in movement. Injuries and disturbances in tendon are common, thus creating extreme difficulties in locomotion. The repair of tendons had always been an enigma in the past. However with the advancement of surgery, the repair of tendon has become possible and the patient return to a normal functioning life.
The present study was launched on twelve mongrel dogs. The achilles tendon was cut surgically and then repaired with two different suture materials i.e. stainless steel and Nylon (No.1). Three groups were made i.e. group A, B and C. Group A for repair of the achilles tendon with stainless steel wire (gauge 24) alongwith a comparison of repair with and without a thomas splint. The group 'B' was repmred with Nylon suture material (No.1) as well as with the comparison of thomas splint application
The group C served as a control group in which no suture material was used, however the effect of thomas splint was compared with and without its application. Of the twelve animals, four were put into each group.
In every group, first the achilles tendon of the right hindlimb was repaired with and without thomas splint. After eight weeks healing, the tendo-achilles of the left hind limb was repaired with the same suture material with and without thomas splint. The wounds were smeared with furacin ointment. Antibiotics were administered 24 hours prior to surgery and continued for 5 days post-surgically. All the dogs were kept under observation for eight weeks postsurgically. however, the total project took 16 weeks. The tendons were tested for repair (healing) by examination, lameness tests, posteuthanasia finding and histopathological studies.
The success rate of the tendons repaired with stainless steel sutures (guage 24) was 50% and with Nylon suture material (No. 1) 100%. The results clearly Indicated that the application of Nylon.
There are no comments for this item.